INDUCTION LOOP FOR LIFTS

induction_loop_for_lifts

Emergency lift communication for the hearing-impaired. The 2N® Induction Loop is an inductive loop that delivers audio to the lift-cabin interior, where it transmits the sound to hearing aids with a built-in inductive sensor. The induction loop is an indispensable assistant in resolving emergency communications from inside the lift for hearing aid users.

 

  • Connect to any lift communicator
  • Take advantage of two independent audio inputs
  • Cover the lift space with a signal for the hearing-impaired

Request Information

Features & Benefits

  • CONNECT TO ANY LIFT COMMUNICATOR

    Don’t replace your lift communicator. All you need to do is to fit the induction loop where required.
  • COVER THE LIFT SPACE WITH A SIGNAL FOR THE HEARING-IMPAIRED

    The induction loop is fitted with an external antenna, which gives the hearing-aid signal full cabin coverage.
  • STANDBY MODE

    During audio signal inactivity, you will appreciate the device switching to a low-power standby mode.
  • EXTERNAL ANTENNA

    The induction loop is fitted with an external antenna, which is designed to be fitted on the lift cabin roof.
  • STANDARDS AND CERTIFICATIONS

    The high-quality design and compatibility with the required standards is proven by TÜV certification EN 81-28/70.
  • TAKE ADVANTAGE OF TWO INDEPENDENT AUDIO INPUTS

    Connect up to two independent audio sources. Use the induction loop not only for emergency calls but also for a floor announcer.
  • ADJUSTABLE VOLUME

    Adjust the volume of the output signal to the induction loop independently for both audio sources.
  • TWO SEPARATE AUDIO INPUTS

    Connect up to two independent signal sources, which you can transmit using the induction loop to the hearing aid.
  • ARBITRARY AUDIO INPUT

    For an existing installation, any audio signal can be used as a source for the induction loop.
Power-supply voltage
8-18 VDC
Supply current for 12 V power supply, load
Full output: 1,1 A
Without signal: 28 mA
Standby: 12 mA
Transition to standby without signal
10 s
Inputs
Galvanically separated by transformers
Input level for full induction
0.5-5 Vef, per config
Output short-circuit resistance
time-unlimited
Frequency response
100 Hz-5 kHz ±3 dB
Temperature range
-20°C – 50°C
Dimensions
80×80×30 mm