Emergency lift communication for the hearing-impaired. The 2N® Induction Loop is an inductive loop that delivers audio to the lift-cabin interior, where it transmits the sound to hearing aids with a built-in inductive sensor. The induction loop is an indispensable assistant in resolving emergency communications from inside the lift for hearing aid users.
- Connect to any lift communicator
- Take advantage of two independent audio inputs
- Cover the lift space with a signal for the hearing-impaired
Features & Benefits
-
CONNECT TO ANY LIFT COMMUNICATOR
Don’t replace your lift communicator. All you need to do is to fit the induction loop where required. -
COVER THE LIFT SPACE WITH A SIGNAL FOR THE HEARING-IMPAIRED
The induction loop is fitted with an external antenna, which gives the hearing-aid signal full cabin coverage. -
STANDBY MODE
During audio signal inactivity, you will appreciate the device switching to a low-power standby mode. -
EXTERNAL ANTENNA
The induction loop is fitted with an external antenna, which is designed to be fitted on the lift cabin roof. -
STANDARDS AND CERTIFICATIONS
The high-quality design and compatibility with the required standards is proven by TÜV certification EN 81-28/70.
-
TAKE ADVANTAGE OF TWO INDEPENDENT AUDIO INPUTS
Connect up to two independent audio sources. Use the induction loop not only for emergency calls but also for a floor announcer. -
ADJUSTABLE VOLUME
Adjust the volume of the output signal to the induction loop independently for both audio sources. -
TWO SEPARATE AUDIO INPUTS
Connect up to two independent signal sources, which you can transmit using the induction loop to the hearing aid. -
ARBITRARY AUDIO INPUT
For an existing installation, any audio signal can be used as a source for the induction loop.
Power-supply voltage | |
8-18 VDC | |
Supply current for 12 V power supply, load | |
Full output: | 1,1 A |
Without signal: | 28 mA |
Standby: | 12 mA |
Transition to standby without signal | |
10 s | |
Inputs | |
Galvanically separated by transformers | |
Input level for full induction | |
0.5-5 Vef, per config |
Output short-circuit resistance | |
time-unlimited | |
Frequency response | |
100 Hz-5 kHz ±3 dB | |
Temperature range | |
-20°C – 50°C | |
Dimensions | |
80×80×30 mm |