2N® Lift1

lift1_2n

The 2N® Lift1 communication solution is designed for two-way emergency communication in the lift. Its typical use is in elevators where communication is required between the cabin and the control center or machine room.

 

  • A comprehensive solution for single lift
  • Powered over a phone line
  • Supports CPC and P100 protocols

Request Information

Features & Benefits

  • A COMPREHENSIVE SOLUTION FOR ONE LIFT

    You can rely on 2N® Lift1 for emergency communication from the lift cabin. Two additional audio units and machine room unit can be attached.
  • SUPPORTS CPC AND P100 PROTOCOLS

    Communicate with the control centre or other monitoring systems using the CPC and P100 protocols.
  • CONFIGURE UP TO 9 USER PROFILES

    Each profile holds a set of parameters. The profile itself is chosen through just one parameter, which changes the entire configuration.
  • 4 VERSIONS OF CABIN UNITS

    You can opt for the basic unit behind the COP panel, a cabled panel unit or a surface mounted unit (‘Compact’ case) or flush mounted.
  • UP TO 6 NUMBERS FOR ALARM CALLS

    2N® Lift1 allows you to specify up to 6 numbers for the alarm call, their usage is based on user settings.
  • WIDE RANGE OF ACCESSORIES

    Choose from a wide range of accessories and extension options, such as the induction loop for communicating with the hearing-impaired persons.
  • POWERED OVER PHONE LINE

    Take advantage of a single pair of wires for communication and power supply combined. When connected to the 2N® EasyGate PRO, the GSM/UMTS gateway, the unit is kept powered up even in the event of a main power failure.
  • SIMPLE CONFIGURATION

    The configuration can be done locally with the supplied configuration software application or remotely using the voice menu. When connected to the 2N® EasyGate PRO GSM/UMTS gateway, the configuration can be changed also using SMS service.
  • ADDITIONAL AUDIO UNITS

    You can add up to two additional audio units to the 2N®Lift1 unit, plus one unit to the lift machine room.
  • MODERNIZATION KITS

    We are providing a customized package including all necessary cabling to match your requirements for lifts modernizations.
  • STANDARDS AND CERTIFICATIONS

    The high-quality design and compatibility with the required standards are proven by TÜV certification EN 81-28/70.
Electrical parameters
Minimum line current: 15 mA, off the hook
Minimum line voltage: 22 V, on the hook
DC voltage drop in the off the hook state: < 9 V, I = 20 mA, < 12 V, I = 50 mA
Resistance on the hook: 1 MΩ >, U = 25..100 V
Impedance off the hook: 220 Ω + 820 Ω paral. 115 nF, 15 to 60 mA
Attenuation: > 14 dB, 15 to 60 mA
Bandwidth: 300 to 3500 Hz, 15 to 60 mA
Impedance while ringing: > 2 kΩC = 0.47 µF, 25 to 50 Hz
Ringtone detection sensitivity: 10 to 20 V, 25 to 50 Hz
Pulse dialling: 40 / 60 ms
Tone-dial levels: -9.0 +2.0/-2.5 dB and -11.0 dB +2.5/-2.0 dB, 15 to 60 mA
Power surge protection – differential between A, B leads: 1000 V (8 / 20 µs)
Note: Any ringing sequence is acceptable.
Switch parameters
Minimum voltage: 9 V AC or DC
Minimum voltage: 24 V AC or DC
Maximum current: 1 A AC or DC
Resistance – open: min 400 kΩ
Resistance – closed: approx. 0.5 Ω
Fuse: resettable
Connection of external indicator elements
Power supply voltage: 12-24 V DC, external source
Maximum switching current: 200 mA
Other parameters
Dimensions of the Universal implementation: 65×130×24 mm
Dimensions of the Kompakt implementation: 100×185×16 mm
Operating temperature range: -20°C – 70°C
lift1_service_tool

2N® LIFT1 SERVICE TOOL

 

With the aid of 2N® Lift1 Service Tool software, you will be able to completely set up the 2N® Lift1 communicator. In addition to this, the software application can, apart from configuration, also be used to perform an upgrade and to change the language version.