The 2N® Lift1 communication solution is designed for two-way emergency communication in the lift. Its typical use is in elevators where communication is required between the cabin and the control center or machine room.
- A comprehensive solution for single lift
- Powered over a phone line
- Supports CPC and P100 protocols
Features & Benefits
-
A COMPREHENSIVE SOLUTION FOR ONE LIFT
You can rely on 2N® Lift1 for emergency communication from the lift cabin. Two additional audio units and machine room unit can be attached. -
SUPPORTS CPC AND P100 PROTOCOLS
Communicate with the control centre or other monitoring systems using the CPC and P100 protocols. -
CONFIGURE UP TO 9 USER PROFILES
Each profile holds a set of parameters. The profile itself is chosen through just one parameter, which changes the entire configuration. -
4 VERSIONS OF CABIN UNITS
You can opt for the basic unit behind the COP panel, a cabled panel unit or a surface mounted unit (‘Compact’ case) or flush mounted. -
UP TO 6 NUMBERS FOR ALARM CALLS
2N® Lift1 allows you to specify up to 6 numbers for the alarm call, their usage is based on user settings. -
WIDE RANGE OF ACCESSORIES
Choose from a wide range of accessories and extension options, such as the induction loop for communicating with the hearing-impaired persons.
-
POWERED OVER PHONE LINE
Take advantage of a single pair of wires for communication and power supply combined. When connected to the 2N® EasyGate PRO, the GSM/UMTS gateway, the unit is kept powered up even in the event of a main power failure. -
SIMPLE CONFIGURATION
The configuration can be done locally with the supplied configuration software application or remotely using the voice menu. When connected to the 2N® EasyGate PRO GSM/UMTS gateway, the configuration can be changed also using SMS service. -
ADDITIONAL AUDIO UNITS
You can add up to two additional audio units to the 2N®Lift1 unit, plus one unit to the lift machine room. -
MODERNIZATION KITS
We are providing a customized package including all necessary cabling to match your requirements for lifts modernizations. -
STANDARDS AND CERTIFICATIONS
The high-quality design and compatibility with the required standards are proven by TÜV certification EN 81-28/70.
Electrical parameters | |
Minimum line current: | 15 mA, off the hook |
Minimum line voltage: | 22 V, on the hook |
DC voltage drop in the off the hook state: | < 9 V, I = 20 mA, < 12 V, I = 50 mA |
Resistance on the hook: | 1 MΩ >, U = 25..100 V |
Impedance off the hook: | 220 Ω + 820 Ω paral. 115 nF, 15 to 60 mA |
Attenuation: | > 14 dB, 15 to 60 mA |
Bandwidth: | 300 to 3500 Hz, 15 to 60 mA |
Impedance while ringing: | > 2 kΩC = 0.47 µF, 25 to 50 Hz |
Ringtone detection sensitivity: | 10 to 20 V, 25 to 50 Hz |
Pulse dialling: | 40 / 60 ms |
Tone-dial levels: | -9.0 +2.0/-2.5 dB and -11.0 dB +2.5/-2.0 dB, 15 to 60 mA |
Power surge protection – differential between A, B leads: | 1000 V (8 / 20 µs) |
Note: Any ringing sequence is acceptable. |
Switch parameters | |
Minimum voltage: | 9 V AC or DC |
Minimum voltage: | 24 V AC or DC |
Maximum current: | 1 A AC or DC |
Resistance – open: | min 400 kΩ |
Resistance – closed: | approx. 0.5 Ω |
Fuse: | resettable |
Connection of external indicator elements | |
Power supply voltage: | 12-24 V DC, external source |
Maximum switching current: | 200 mA |
Other parameters | |
Dimensions of the Universal implementation: | 65×130×24 mm |
Dimensions of the Kompakt implementation: | 100×185×16 mm |
Operating temperature range: | -20°C – 70°C |
2N® LIFT1 SERVICE TOOL
With the aid of 2N® Lift1 Service Tool software, you will be able to completely set up the 2N® Lift1 communicator. In addition to this, the software application can, apart from configuration, also be used to perform an upgrade and to change the language version.